Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: FBCDZ-12-№35
Brand: An hong
Number Of Motor: 2 groups
Wind Pressure: 900-3250 Pa
Color: customizable
Material: titanium steel
Selling Units: | tower |
---|
Ventilation fan debugging
1. Before debugging the ventilation fan, check the air leakage in the tunnel to ensure smooth ventilation. When using pressure reduction or direct starting, start the second stage of the cyclone first, and then start the first stage; When using variable frequency starting, the first and second stages of the cyclone should be started simultaneously.
2. After the ventilation fan is running, measure whether the ventilation fan air volume meets the required air volume for the mine. If it does not meet the requirements, adjust the installation angle of the fan blades or use a frequency converter to adjust the motor speed.
3. Users can measure the operation status of the ventilation fan based on its on-site performance, and draw a mine performance curve to adjust the working conditions.
The FBC (D) Z-series explosion-proof extraction (counter rotating) Axial Flow Ventilation Fan for coal mine surface can be used as a replacement product for large, medium, and small coal mines, as well as a product for new mines. The ventilation fan is equipped with non-stop air injection and oil discharge devices, which can add lubricating oil during operation. When the machine is shut down, the oil discharge port cover can be opened to discharge waste oil.The fan blades and the inside and outside of the casing have undergone multiple anti-corrosion and moisture-proof treatments, allowing the fan to operate for a long time in a humid environment, effectively solving the problem of corrosion caused by other conditions on the fan.
The ventilation fan blades have steel hollow riveted structure and high-strength cast (forged) aluminum structure, and the installation angle can be adjusted. Users can adjust according to the required air volume and pressure in the front and rear stages; It can also be adjusted according to the frequency conversion control system to meet usage requirements and achieve energy-saving effects. At the same time, the unique blade structure design combined with a silencing device controls the noise during the operation of the ventilation fan within the national noise standards, reducing environmental pollution.
Our main products include: Coal mine fan,Fan distribution cabinet,Local ventilation fan,Equipment Maintenance Parts,mine ventilating fan,Tunnel Fan.